Asked By
dean mccoy
0 points
N/A
Posted on - 06/18/2012
Has anyone encountered this problem?
I was in the middle of deploying my work in cRIO-9104, but it “completed with errors”.
I was working with an NI-9853 at that time.
I got a screenshot of the error during the Deployment progress.
Deploying CAN Mode.ctl (2.09 K)
Deploying ncclose.vincClose.vi loaded with errors on the target and was closed.
LabView: Failed to load shared library nican.*:
ncCloseObject:C on RT target device.
Deployment completed with errors
Please, I need help working around this problem.
Thank you
Error Deploying My Work In cRIO-9104
This error resulted from NI-CAN driver which has not installed in CompactRIO. NI-CAN driver is required to be installed on both development machine and CompactRIO. This issue can be fixed in Measurement & Automation Explorer (MAX) by following the simple steps provided below :
1. Firstly, open the controller and right-click on Software.
2. Next , select Add/Remove Software and click Custom Software Installation.
3. Select Next and choose NI-CAN.
4. Finally, click Install the feature.
I hope this little help benefit you . Thanks .